Skip to main content

Connect an attendance machine

Each physical reader is one Attendance Machine record. A reader on the company network is read by the attendance collector (Sync Mode PULL, by IP address and port). A reader at a remote site sends its punches to the server itself (Sync Mode ADMS, by serial number). Each employee is then matched to the reader by his enrolment number on the device.

Who
The implementation consultant with the client's IT
Needs first
The reader installed, with its address and port or its serial number. The attendance collector installed by whoever set up the server

Before you start​

  • Get from IT, per reader: is it on the same network as the collector, its IP address and port, its serial number, its model and its communication password.
  • The only manufacturer on the list today is ZKTeco. A reader of another make needs to be checked with support before it is promised.
  • For a reader that sends to the server (ADMS), the legal entity needs its time zone set. Without it the server cannot place the punches in time and discards them.
  • One reader, one record. Registering the same reader twice doubles every punch.

Steps​

  1. Open Attendance Machine. Enter Machine, Machine Name, Manufacturer, Model and Site.
  2. Enter Identification and Password as set on the device.
  3. Pick the Sync Mode:
    • PULL for a reader on the company network. Enter IP Address and Port. ZKTeco readers usually use port 4370.
    • ADMS for a reader that sends to the server over the internet. Enter its Serial Number.
    • KIOSK is not a reader. See Set up the face kiosk.
  4. For PULL, set how often it is read: Read Every (Minutes) with a Read Only From and Read Only Until window, or a named Schedule from Schedule Machine for fixed times.
  5. Save. Watch Device Status and Last Heart Beat Date. Pending means the device has not been reached yet.
  6. On Employee Basic Information, give each person the Machine No and the Machine Enrolment No he is enrolled under on the reader. It defaults to his employee number.
  7. Have two or three people punch, and look for the punches on Employee Attendance.

Check it worked​

  • Device Status reads online, and Last Synced Date moves forward.
  • The test punches show in the Actual Time In and Actual Time Out columns on Employee Attendance.

If it goes wrong​

  • "Machine name already exists! Please enter different name." Two readers cannot share a name. Add the location to it.
  • The IP address and port, or the serial number, are already registered. The same reader is already on the list under another code. Use that record.
  • A serial number is needed. ADMS has no address, so the serial number is its only identity.
  • An IP address is needed. PULL dials the reader, so it needs one.
  • A port is needed. Enter the reader's port. ZKTeco readers use 4370.
  • The enrolment number is already used. Two employees hold the same number on the reader, so every punch would count for both. Clear it from the wrong person.
  • The reader stays Pending. The collector has not reached it. Check that the collector is running at that site and that Stop Fetching is not ticked.
  • Punches stopped on one reader. Compare Log Count with Log Capacity. A full reader stops recording.
  • Punches land on the wrong day or the wrong time. The reader's own clock is wrong. Correct its date and time on the device.
  • Everybody is absent on one day. A reader did not sync. Fix the reader, not the people.
  • A reader is away for repair. Tick Stop Fetching. Untick it when it is back.